Easi-Slide Pipes

Note: All junctions are to be fitted on their side. Junctions are not designed for vertical surface compaction.

Easi-Flex Anchor System Diagram

Fastfits Available 150mm Super sleeve made to order

 

Easi-slide Spigot Butt Pipes

Easi-slide Spigot Butt Pipes

 

Easi-slide Oblique (45°) Reduced Junction (Wet-Cast Ex-Alnwick)

Easi-slide Oblique (45°) Reduced Junction (Wet-Cast Ex-Alnwick)

 

Easi-slide Two Piece Bends (Wet-Cast Ex-Alnwick)

Easi-slide Two Piece Bends (Wet-Cast Ex-Alnwick)

 

Easi-slide Lifting Chains

Easi-slide Lifting Chains

 

Handling/Lifting Instructions

Jacking Pipes Easi-Lift System

Pipe Diameters DN1800 to DN2400 are designed and manufactured to incorporate Easi-Lift jointing and lifting system.

Easi-Lift System

To lift the pipes, select the two short legs A and B on the chain set. Place the spherical coupling over the cast in anchor and engage by turning the tail of the head link down to the concrete. The pipe can then be lifted as normal. Never pass slings or other lifting appliances through the barrel and never lift more than one pipe at a time.

Jointing

Ensure that the seal is of the correct size, and is not damaged.

Jacking Pipes Jointing - Ensure the tension is even
Ensure pipe sockets and spigots are not damaged. Position the rubber ring on the end of the spigot end.

Do not use Lubricants when jointing Easi-Slide Pipes Ensure each pipe to be laid is aligned with the laid pipeline and is fully supported along its length Some methods of joining pipes are shown below.

Jointing

To joint the pipe using the chain system. Attach the long leg C to the already laid pipe and the short leg B to the pipe to be laid. Take up the slack in the chains with the lifting pulley over the anchor of the laid pipe, and increase the upward force to joint the pipes. When jointed, ensure that there is no excessive slew or misalignment, this can easily be checked by reference to the joint gap.

Jacking Pipes Jointing - Joint Gap

Notes:

  1. All dimensions are in mm.
  2. Weights in kg are based on a concrete density of 2500kg/m³.
  3. Where relevant pipes are manufactured in accordance with BS EN 1916:2002.
  4. Note right hand or left hand junctions (viewed socket to spigot) should be specified when ordering
    reduced junctions in pipe diameters DN1800 and above.
  5. Note lifting chains are not suitable for joining purposes in pipes of diameter DN2400.
  6. All junctions to be installed on their side only.