Wide Wall Manhole Chambers

A 130mm thick Wide Wall Manhole Chamber in combination with the Easi Base unit, provides a sealed watertight manhole system. No concrete back fill required in accordance with sewers for adoption vs 6.

 

Advantages

  • Watertight on construction
  • Lifting loops built into wall
  • Safer lifting system (spherical head lifting system)
  • Cost saving - No back fill with concrete
     


Wide Wall Manhole Chamber Lifting Loops Wide Wall Manhole Chamber Wide Wall Manhole Chamber Thickness

 

Wide Wall Dimensions

Wide Wall Manhole Chamber Dimensions

 

FP McCann wide wall manholes have been designed with a tongue and groove dimension to accomodate the use of bituminous sealant.  An FP McCann approved sealant should be used at all times.  The sealant requirement for wide wall manholes is 12mm x 120mm x 6mm.  When placing sealing strip into position during installation, the ends of the strips must be overlapped by a minimum of 30mm and cut at an angle of 60 degrees.  The cut ends must then be pressed together.