TESTS CARRIED OUT |
|
|
| |
All pipes and manholes are manufactured in accordance with BSEN 1916:2002 and BSEN 1917:2002 and complimentary standards. |
|
| |
|
|
|
|
| |
HYDROSTATIC TEST |
|
|
|
| |
Flexible jointed pipes must withstand an internal hydrostatic pressure of 0.5 bar for 15 minutes without any signs of leakage. |
|
| |
|
|
|
|
| |
|
|
|
|
| |
LOAD TEST |
|
|
|
| |
All pipe products are tested to the appropriate proof or crushing strength requirement specified in BSEN 1916:2002. |
|
| |
|
|
|
|
| |
BENDING MOMENT RESISTANCE (BMR TEST) |
|
|
| |
Pipes up to and including DN 250 with an effective length greater than 6 times the external diameter. |
|
| |
|
|
|
|
| |
|
|
|
|
| |
JOINT TYPE TESTS |
|
|
| |
Completing deflection, and shear tests proves the water tightness of flexible joints. These are carried out at an internal hydrostatic pressure of 5 bar for a period of 15 minutes without any sign of leakage. |
|
| |
|
|
|
|
| |
|
|
|
|
| |
ANCHORAGE PULL-OUT TEST |
|
|
| |
Type tests for pull load on cast-in steel anchorages are carried out. The test applies a load of 2.5 times the weight of the pipe to each anchorage without vibration or sudden shock. |
|
| |
|
|
|
|
| |
|
|
|
|
| |
OTHER TESTS |
|
|
| |
Among other tests carried out are, Depth of cover to reinforcement, water absorption, Permissible deviation from straightness, and various product finish checks as required by the British and European Standards. |
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
| |
TABLE: TESTS AND TOLERANCES |
|
| |
The following table indicates Crush Tests Loads applied during testing to prove strength class of the manufactured pipe. |
|
| |
|
|
|
|
| |
The table also indicates Recommended Joint Gap and Max. Joint Deflection when jointing on site. |
|
| |
|
|
|
|
| |
PIPE DN |
Crush Test Load |
Recommended Joint Gap (mm) |
Max. Joint Deflection |
KN/m |
|
Degree |
225 |
27 |
7.8 |
2 |
300 |
36 |
8.8 |
2 |
375 |
45 |
8.8 |
2 |
450 |
54 |
8.8 |
2 |
525 |
63 |
8.8 |
2 |
600 |
72 |
8.7 |
2 |
675 |
81 |
8.7 |
2 |
750 |
90 |
11.2 |
1 |
825 |
99 |
11.2 |
1 |
900 |
108 |
11.2 |
1 |
1050 |
126 |
11.2 |
1 |
1200 |
144 |
13.6 |
1 |
1350 |
162 |
15 |
0.5 |
1500 |
180 |
13.7 |
0.5 |
1800 |
216 |
17.7 |
0.5 |
2100 |
252 |
17.6 |
0.5 |
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
Technical Assistance |
|
|
|
| |
Contact FP McCann Quality on: |
|
|
|
| |
England & Wales : |
T: 01530 240000 |
F: 01530 240013 |
|
| |
N.Ireland, Ireland & Scotland : |
T: +44 (0) 28 7964 2558 |
F: +44 (0) 28 7954 9993 |
|
| |
|
|
|
|
| |
|
|
|
|
| |
For Technical Reference: |
|
|
|
| |
FP McCann Jacking Brochure will be available to download soon. |
|
|
| |
Visit the Concrete Pipeline Systems Association (CPSA) "Complete Technical Guide" |
|
| |
Reference can also be made to WRc's Sewers for Adoption 6th edition and Civil Engineering Specification for Water Industry 6th edition. |
|
| |
|
|
|
| |
|
|
|
| |
Additional Information can be attained by: |
|
|
| |
Visit the CPSA website at: www.concretepipes.co.uk |
|
|
| |
Visit the Pipe Jacking Association website at: www.pipejacking.org |
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|